Four certified roofing systems protect South Florida homes

Every roof assembly we specify is certified under current Miami-Dade Notice of Acceptance product approvals and complies with High Velocity Hurricane Zone provisions.

The subtropical climate of South Florida subjects roofing materials to extreme ultraviolet solar radiation, ninety percent relative humidity, torrential convective squalls, and cyclic hurricane winds. A roofing system that functions adequately in Georgia or North Carolina will fail prematurely in Miami if its underlayment degrades or its fasteners shear under uplift loads.

Below are our four core roofing disciplines. Every replacement proposal includes full deck tear-off, 8d ring-shank re-fastening to rafter trusses, secondary water barriers, municipal permit acquisition, and magnetic clearance of your perimeter.

Architectural asphalt shingles withstand hurricane gusts when anchored over re nailed wood deck sheathing

Dimensional fiberglass asphalt shingles provide resilient, cost-effective storm protection when paired with code-mandated deck attachment and self-adhering modified bitumen underlayment.

$9,000 – $18,000 USD per job
Installation of secondary self-adhering water barrier underlayment along roof drip edge
High-temp self-adhering secondary water barrier applied directly to CDX plywood substrate along eave drip edge Miami-Dade TAS 103 Approval

Class-4 impact-resistant shingles withstand sustained wind velocities up to 130 miles per hour under TAS 107 testing standards. Our crews strip all existing shingle layers and organic felt down to the bare plywood sheathing. We re-nail the wood deck with 8d ring-shank nails on six-inch centers, bond a high-temperature self-adhering secondary water barrier across the entire surface, install heavy 26-gauge drip edge flashings, and anchor every shingle with six corrosion-resistant mechanical roofing nails.

This system suits single-family pitched residences seeking structural hurricane compliance, clean architectural shadow lines, and straightforward insurer wind mitigation credits.

Wind Uplift Rating 130 mph • TAS 107 / ASTM D3161
Underlayment Barrier Self-adhering polymer modified bitumen (TAS 103)
Deck Fastener Schedule 8d ring-shank nails on 6" centers into trusses
Typical Job Turnaround 2 – 3 days post-permit inspection
Permit & Engineering Full Miami-Dade Product Approval filed
Request Shingle Inspection

Standing seam metal panels eliminate exterior screw penetrations that fail under intense South Florida sunshine

Continuous vertical seams with concealed stainless steel expansion clips allow thermal movement while locking the roof envelope against Category 5 storm uplift.

$18,000 – $45,000 USD per job
Macro detail of standing seam metal roof interlocking seam and concealed clip attachment
Concealed stainless steel clip attachment locking 24-gauge standing seam rib to deck without exterior panel penetrations Uplift Rated 175+ mph

Standing seam metal represents the highest performance building envelope shield available for South Florida coastal environments. Built with 24-gauge structural Galvalume steel or .032 marine-grade aluminum, the system utilizes continuous vertical ribs with mechanically locked seams that conceal all fasteners beneath the surface.

Because there are zero exterior exposed screws or neoprene rubber washers to bake dry and leak in tropical heat, standing seam profiles provide five decades of watertight durability. Stainless steel expansion clips hold panels firmly to the deck while permitting smooth thermal expansion and contraction as roof surface temperatures fluctuate between night chills and 140-degree midday sun.

Engineered for extreme hurricane wind uplift resistance exceeding 175 miles per hour, this system is ideal for modern architectural residences, coastal barrier island properties, and low-slope roof lines where tile dead-weight cannot be accommodated.

Wind Uplift Rating 175+ mph • TAS 125 / UL 580 Class 90
Material Gauge & Alloy 24-gauge AZ50 Galvalume / .032 marine aluminum
Fastener Architecture 100% concealed expansion clips (zero exposed screws)
Coating Technology Kynar 500 / Hylar 5000 PVDF resin finish
Substrate Barrier High-temp synthetic membrane rated to 250°F
Request Metal Inspection

Concrete and clay barrel tiles require structural adhesive foam and multi ply waterproof underlayment

Spanish S-tile and flat concrete slab profiles deliver architectural distinction backed by dual-layer modified bitumen underlayment and polyurethane foam anchoring.

$22,000 – $55,000 USD per job
Craftsman setting Spanish barrel tile into hurricane-rated expanding adhesive foam
Roofing craftsman setting Spanish terracotta clay barrel tile into high-wind structural expanding foam bead along slope TAS 101/102 Mechanical Compliance

Spanish barrel clay tile and flat concrete slab tiles define the classic architectural landscape of Coral Gables, Coconut Grove, and Miami-Dade residential communities. While high-density tiles endure decades of solar bombardment, the true waterproofing barrier is the multi-ply underlayment beneath them.

Dual-layer modified bitumen membranes form the primary moisture seal, hot-mopped with type IV asphalt or double-bonded with high-tensile polymer self-adhering sheets. Instead of old-fashioned mortar pads that crumble under vibration, we secure tiles with closed-cell polyurethane hurricane adhesive foam meeting TAS 101/102 mechanical testing criteria.

Our technical team performs structural dead-load verification on your truss system before staging pallets. If your rafters require engineering reinforcement for high-density clay barrel tiles, we frame the required structural sistering before pulling building permits.

Wind Uplift Rating 150+ mph • TAS 101 / TAS 102 test protocols
Attachment Method Polyurethane closed-cell adhesive foam or stainless screws
Underlayment System Two-ply modified bitumen hot-mop or self-adhering
Dead Load Consideration 900 – 1,200 lbs per roofing square (engineering checked)
Eave Detailing Perforated bird-stop closures & 26-ga copper/galv drip edge
Request Tile Inspection

Targeted structural leak repairs resolve flashing failures before water rots your interior truss framing

Our repair technicians uncover the root cause of water intrusion, replace rotten decking, and install soldered metal transitions rather than applying cosmetic surface patches.

$523 – $5,230 USD per job
Sheet metal craftsman crimping waterproof valley flashing on roof repair project
Metal craftsman hand-seaming open copper valley flashing pan on residential roof repair in Miami-Dade Flashing Replacement • 4931 SW 75th Ave Yard Dispatch

Not every water intrusion issue requires a fifty-thousand-dollar roof replacement. When an otherwise sound roof develops targeted leaks at flashing intersections, plumbing vent boots, or valley channels, our repair specialists diagnose the exact entry point and execute permanent structural repairs.

Surface mastic smeared over wet underlayment provides only false security. Instead, technicians remove surrounding tiles or shingles, peel back dried underlayment, inspect underlying rafter tails and sheathing for fungal rot, replace damaged plywood sections, install custom-bent metal valley pans or soldered lead boot collars, and tie the waterproof membrane back into the field roof with proper overlapping laps.

A minor leak left through one tropical rainy season rots truss tails and converts a $523 valley repair into a $5,230 structural rebuild involving interior drywall and engineering framing.

Repair Scope Range Minor flashing reseal to extensive valley re-decking
Diagnostic Procedure Attic truss moisture mapping & exterior slope sounding
Flashing Fabrication Hand-seamed 16 oz copper or 26-gauge galvanized steel
Response Time Priority field dispatch from 4931 SW 75th Ave facility
Request Repair Dispatch

Every written quote details six variables so homeowners know exactly what they are paying for

Detailed breakdowns prevent unexpected costs by providing fully itemized material teardown and permit schedules before work starts.

When comparing roofing bids in South Florida, low estimates frequently omit essential tasks mandated by the Florida Building Code, only to bill them later as mandatory change orders once your roof is exposed to rain. At A&E Brothers Roofing, every binding proposal incorporates six clear parameters:

  • Roof Square Footage: Accurate physical measurement derived from manual sounding and high-resolution aerial mapping.
  • Material Profile & Gauge: Exact brand, model, gauge, and Miami-Dade Notice of Acceptance number specified in writing.
  • Slope & Roof Pitch: Scaffolding and harness staging required for steep 7:12+ pitches compared to standard low slopes.
  • Tear-Off & Disposal: Complete removal of existing shingle or tile layers, hydraulic trailer hauling, and transfer station fees.
  • Deck Sheathing Allowance: Unit cost per sheet of 5/8-inch CDX plywood and linear footage of 2×6 rafter repair pre-agreed.
  • Permits & Wind Mitigation: Building department filing fees, in-progress deck inspection attendance, and uniform mitigation verification.

For preliminary cost projections tailored to your home’s square footage, use our interactive unit price estimator on the homepage or call our dispatch desk directly at 305-815-7208.